HVAC AIR BOOSTERS
|
|
|
|
Ductwork air booster
Ref: Improve air flow for Heating & Air ductworks
systems
Product Description
Air Boosters improve air flow and distribution of conditioned air to
“problem” rooms in homes and businesses. They are mounted in ductwork
and improve air flow by up to 1400 cfm, improving heating/cooling
system efficiency and saving energy. There are nine models designed for
round or square ducts up to 14" in diameter.
Heavy-Duty Model for Round and Square
Metal ductwork

AB-1
Increase air flow to problem rooms up to 305 CFM
Unique design will work with square, rectangular and round metal
ductwork
Easy installation
Can be used with forced air, oil, gas and electric furnaces and heat
pumps
The most durable, long lasting air booster on the market

For Square or Round Metal
Duct

AB-2
Increase air flow to problem rooms up to 220 CFM
Designed for round or rectangular metal ducts 6” or larger
Easy installation
Heavy-duty motor
Motor is designed for years of trouble free operation

For Round Metal Duct and Flex
ductwork

AB-3
Increase air flow to problem rooms from 80 CFM to 1400 CFM depending
on model
Designed for use in 4", 5", 6", 8", 10", 12" and 14" round metal or
flexible ductwork
Easy installation
Heavy-duty motor
Motor is designed for years of trouble free operation

ABA-1
Optional Air Booster Activator for automatic, year-round operation of
Air Boosters.

How HVAC Air Boosters Work ? Air Boosters are
typically wired parallel with the furnace or air conditioner blower.
When the blower activates, the Air Booster will activate. The Air
Booster can also be wired to an on/off switch to provide additional air
flow only when needed. For remote locations, where wiring into the
furnace is not practical, the Air Booster Activator (ABA-1) is
available. The ABA-1 senses an air pressure change in the duct when the
blower activates and starts the Air Booster.
| Electrical Data |
Thermal or Impedance Protection |
Maximum Temp Rating (F) |
Air Flow Capacity CFM Up To |
| Model |
Volts (AC) |
Amps |
Hz |
Watts |
RPM |
| AB-1 |
120 |
.5 |
60 |
38 |
1725 |
Yes |
180° |
305 |
| AB-2 |
120 |
.6 |
60 |
35 |
3000 |
Yes |
180° |
220 |
| AB-4 |
120 |
.29 |
60 |
19 |
3000 |
Yes |
155° |
80 |
| AB-5 |
120 |
.5 |
60 |
30 |
3000 |
Yes |
155° |
165 |
| AB-6 |
120 |
.6 |
60 |
35 |
3000 |
Yes |
180° |
225 |
| AB-8 |
120 |
.8 |
60 |
45 |
3000 |
Yes |
160° |
425 |
| AB-10 |
120 |
.4 |
60 |
37 |
1450 |
Yes |
180° |
600 |
| AB-12 |
120 |
1.1 |
60 |
91 |
1500 |
Yes |
180° |
1050 |
| AB-14 |
120 |
1.1 |
60 |
91 |
1500 |
Yes |
160° |
1400 |

|
|
|
|
|
|
|
|
Service Territory - Kinston, Deep Run, Pink Hill, Seven
Springs, Trenton, Comfort, Dover, Cove City, LaGrange, Snow Hill, Grifton, Ayden, Farmville, Bethel, Greenville,
Winterville, Grimesland, Simpson, Blackjack, Vanceboro, Oriental, New Bern, Emerald Isle, Atlantic Beach, Pine
knoll shores, James City, Havelock, Pollocksville, Goldsboro, Lenoir County, Wayne County, Pitt County, Craven
County, Pamlico County, Onslow County, Jacksonville, North Carolina, NC, Eastern North Carolina.
|
|
|